Welch Allyn 105920 NIBP Pump Assembly Service Kit
The Welch Allyn 105920 NIBP Pump Assembly Service Kit is a manufacturer-specified replacement solution for servicing the non-invasive blood pressure pump assembly in compatible Welch Allyn patient monitoring equipment. Designed for professional maintenance applications, this service kit supports restoration of the pneumatic function required by the monitor’s NIBP measurement system.
Product Purpose and Features
- Replacement pump assembly service kit for a non-invasive blood pressure subsystem
- Manufactured by Welch Allyn
- Identified by catalog and part number 105920
- Intended for maintenance and repair by qualified biomedical service personnel
- Supports service of the pneumatic assembly used during automated blood pressure measurement
- Manufacturer-specific component for compatible Welch Allyn equipment
Technical Specifications
- Manufacturer: Welch Allyn
- Catalog number: 105920
- Part number: 105920
- Product name: NIBP Pump Assembly Service Kit
- Product type: Medical equipment service kit
- System: Non-invasive blood pressure measurement
- Abbreviation: NIBP
- Component function: Pneumatic pump assembly service replacement
- Application: Patient monitor maintenance and repair
Compatible Medical Devices
The Welch Allyn 105920 service kit is intended for compatible configurations of the Welch Allyn Connex Vital Signs Monitor 6000 Series that specify part number 105920 in the applicable service documentation. Compatibility should be confirmed by checking the monitor model, hardware configuration, serial-number range, and current Welch Allyn service parts list before installation.
Usage Instructions
- Confirm that Welch Allyn catalog number 105920 is specified for the exact monitor configuration being serviced.
- Turn off the medical device, disconnect external power, and isolate the internal battery according to the official service procedure.
- Observe applicable electrostatic-discharge precautions before opening the equipment.
- Access the NIBP subsystem and remove the existing pump assembly by following the device-specific Welch Allyn service manual.
- Install the replacement assembly without pinching, stretching, or incorrectly routing pneumatic tubing and electrical connections.
- Reassemble the monitor and perform all required NIBP functional, pneumatic leak, safety, and calibration checks specified by the manufacturer.
- Return the device to clinical use only after it passes the complete post-service verification procedure.