Siemens 5766675 GRID 15/80 F115 (Tested)
Siemens 5766675 GRID 15/80 F115 Tested X-Ray Anti-Scatter Grid
The Siemens 5766675 GRID 15/80 F115 is a tested, focused X-ray anti-scatter grid designed for compatible Siemens medical imaging equipment. Installed between the patient and image receptor, the grid absorbs a portion of scattered radiation before it reaches the detector, helping preserve image contrast during diagnostic X-ray examinations.
Purpose and Key Features
- Focused anti-scatter grid for medical X-ray imaging applications
- 15:1 grid ratio for scatter reduction
- Grid density of 80 lines per centimeter
- Nominal focal distance of 115 cm
- Original Siemens component with catalog number 5766675
- Supplied in tested condition
Technical Specifications
- Manufacturer: Siemens
- Catalog number: 5766675
- Model and designation: GRID 15/80 F115
- Product type: Focused X-ray anti-scatter grid
- Grid ratio: 15:1
- Grid density: 80 lines/cm
- Nominal focal distance: 115 cm
- Condition: Tested
Compatible Medical Equipment
The Siemens 5766675 grid is intended for Siemens medical X-ray systems, detector assemblies, and Bucky units whose manufacturer documentation specifies catalog number 5766675 or the exact GRID 15/80 F115 configuration. Compatibility must be confirmed using the equipment model, serial number, installed image receptor, and OEM parts documentation. This focused grid should only be used in systems designed for a 15:1 ratio, 80 lines/cm density, and 115 cm focal distance.
Installation and Usage Instructions
- Confirm that Siemens part number 5766675 is approved for the specific medical device and configuration.
- Inspect the grid for physical damage, deformation, or contamination before installation.
- Install the component in the designated grid holder or Bucky assembly according to Siemens service documentation.
- Observe the indicated tube-side orientation and align the grid center with the central X-ray beam.
- Maintain the specified 115 cm focal distance and correct tube alignment to reduce the risk of grid cutoff.
- After installation, perform the required image-quality, alignment, and automatic exposure control checks in accordance with the equipment manufacturer’s procedures.
- Installation and functional verification should be completed by qualified medical equipment service personnel.
Order Siemens 5766675 from Partsformed
Partsformed supplies the tested Siemens 5766675 GRID 15/80 F115 for professional maintenance and replacement requirements. Customers benefit from high-quality products, competitive prices, and worldwide shipping. Verify the catalog number and system configuration before ordering to ensure correct compatibility.