Olympus WA00014A HF CABLE BIPOLAR
Olympus WA00014A HF Cable Bipolar
Product Description
The Olympus WA00014A HF Cable Bipolar is a reusable electrosurgical cable designed to transfer high-frequency electrical energy between a compatible Olympus electrosurgical generator and bipolar endoscopic instrumentation. Manufactured by Olympus, this 4 m cable supports bipolar electrosurgical procedures performed with an approved Olympus system configuration.
The WA00014A bipolar HF cable provides the connection required for controlled energy delivery from the generator to the connected instrument. Its extended length facilitates practical equipment positioning in operating and procedure rooms. The cable is an accessory and must be used only with compatible devices, instruments, and settings specified by Olympus.
Technical Specifications
- Manufacturer: Olympus
- Catalog number: WA00014A
- Product type: Bipolar HF electrosurgical cable
- Energy configuration: Bipolar
- Cable length: 4 m
- Application: Connection of compatible bipolar endoscopic instruments to an Olympus electrosurgical generator
- Use category: Reusable electrosurgical accessory
Compatible Medical Equipment
The Olympus WA00014A bipolar cable is intended for use with the Olympus ESG-400 electrosurgical generator and compatible Olympus bipolar endoscopic instrumentation, including approved configurations of the Olympus OES Pro resectoscope and TURis bipolar resection system. Compatibility must be confirmed for the complete generator, working element, electrode, and cable configuration before use.
Purpose and Key Features
- Transfers high-frequency energy to compatible bipolar surgical instrumentation.
- Supports bipolar electrosurgical and endoscopic resection applications.
- Provides a 4 m working length for flexible generator placement.
- Designed for integration with approved Olympus electrosurgical equipment.
- Reusable construction supports repeated clinical use when inspected and reprocessed according to the Olympus instructions.
Usage Instructions
- Confirm that WA00014A is specified for the generator, working element, electrode, and procedure being used.
- Before connection, place the electrosurgical generator in standby or switch it off according to the generator instructions.
- Inspect the cable, insulation, connectors, and strain-relief areas. Do not use the cable if it is damaged, deformed, contaminated, or has exposed conductors.
- Insert each connector fully into the designated bipolar socket without twisting, forcing, or modifying the connection.
- Route the cable to prevent sharp bends, crushing, tension, contact with hot surfaces, or interference with the sterile field.
- Operate the generator only with settings approved for the connected bipolar instrument and the intended procedure.
- After use, disconnect the cable by holding the connector rather than pulling on the cable.
- Clean, disinfect, sterilize when applicable, inspect, and store the cable strictly according to the current Olympus reprocessing instructions.
The WA00014A should be handled only by trained medical personnel familiar with bipolar electrosurgery. Always follow the current Olympus instructions for use and the healthcare facility’s electrosurgical safety procedures.
Order Olympus WA00014A from Partsformed
Partsformed supplies the Olympus WA00014A HF Cable Bipolar and other high-quality medical equipment products at competitive prices. Worldwide shipping is available to support hospitals, surgical centers, clinics, and medical equipment service organizations in multiple regions.