Inspire Innovations international limited.
Type the part number or keyword in the search box. If you do not know the catalog number, you can find the product by category or by manufacturer. To find a product by device model, first select the manufacturer.
Olympus A0336.1 HF Monopolar Cable
Olympus A0336.1 HF Monopolar Cable
The Olympus A0336.1 HF Monopolar Cable is a high-frequency connection cable manufactured by Olympus for compatible monopolar electrosurgical systems. It provides the electrical link between a supported Olympus monopolar surgical instrument and an HF electrosurgical generator. Designed for professional medical use, this cable supports controlled transfer of high-frequency energy during procedures performed with compatible equipment.
Purpose and Key Features
- Connects compatible Olympus monopolar instruments to an electrosurgical HF generator.
- Supports monopolar high-frequency electrosurgical operation.
- Suitable for Olympus surgical configurations whose instructions specify cable model A0336.1.
- Separate accessory that can be inspected and replaced without replacing the connected instrument.
- Manufactured by Olympus for use in professional healthcare environments.
Technical Specifications
- Manufacturer: Olympus
- Model: A0336.1
- Catalog number: A0336.1
- Product type: HF monopolar cable
- Electrosurgical configuration: Monopolar
- Primary function: High-frequency electrical connection between a compatible monopolar surgical instrument and HF generator
- Application: Electrosurgical and endoscopic surgical systems
- Intended users: Trained medical and reprocessing personnel
Compatible Medical Equipment
The Olympus A0336.1 cable is intended for Olympus monopolar surgical instruments and electrosurgical HF generators whose operating documentation identifies A0336.1 as an approved connection cable. Compatibility depends on the specified cable model, mating connectors, generator output configuration, and the instructions for the complete electrosurgical system.
- Compatible Olympus monopolar resection and operative instruments that specify model A0336.1
- HF electrosurgical generators with the corresponding monopolar connection and documented support for this cable
- Olympus electrosurgical system configurations that list catalog number A0336.1 among approved accessories
Before installation, verify the model number in the manuals for both the surgical instrument and generator. Connector fit alone does not confirm electrical or clinical compatibility.
Usage Instructions
- Confirm that the cable is listed as compatible with the selected Olympus instrument and HF generator.
- Place the generator in the off or standby state before making connections.
- Inspect the cable, insulation, plugs, and strain-relief areas. Do not use it if there are cracks, exposed conductors, loose components, deformation, or other visible damage.
- Connect each end only to its designated instrument and generator interface, following the equipment manufacturer’s instructions.
- For monopolar operation, install and monitor the required patient return electrode according to the generator and electrode instructions.
- Perform the prescribed system and function checks before beginning the procedure.
- During use, keep the cable away from sharp edges, excessive tension, hot surfaces, and areas where it may be pinched.
- After the procedure, return the generator to standby or switch it off, then disconnect the cable by holding the plugs rather than pulling on the cable.
- Clean, disinfect, reprocess, inspect, and store the cable strictly according to the current Olympus instructions for use and the healthcare facility’s validated procedures.
Ordering from Partsformed
Partsformed supplies the Olympus A0336.1 HF Monopolar Cable with worldwide shipping, competitive prices, and a commitment to high-quality medical products. Confirm the catalog number and compatibility with your existing Olympus electrosurgical equipment before ordering.
