Newport Medical (Covidien) AG-AP1085 CONTROL MODULE CABLE
Newport Medical (Covidien) AG-AP1085 Control Module Cable
The Newport Medical (Covidien) AG-AP1085 Control Module Cable is a manufacturer-specified internal interconnect component for the Newport e360 ventilator system. It provides the designated electrical connection for the ventilator’s control module and is intended for professional maintenance, repair, or replacement of the corresponding installed cable.
Product Features
- Purpose-built control module cable for compatible Newport Medical ventilator equipment
- Catalog number AG-AP1085 supports precise part identification
- Designed for installation in the original cable position and routing path
- Suitable for corrective maintenance and replacement of a damaged or defective control module connection
- Medical equipment service component intended for installation by qualified technical personnel
Technical Specifications
- Manufacturer: Newport Medical (Covidien)
- Model and catalog number: AG-AP1085
- Product type: Control module cable
- Application: Internal ventilator control module interconnection
- Compatible equipment family: Newport Medical e360 ventilator system
- Installation category: Service replacement component
- Intended users: Qualified biomedical engineers and authorized medical equipment service technicians
Compatible Medical Device
The AG-AP1085 control module cable is intended for use with the Newport Medical e360 ventilator. Before installation, confirm the device model, configuration, and existing cable part number against the ventilator’s service documentation and equipment records.
Installation and Usage Instructions
- Remove the ventilator from clinical use and disconnect it from AC power and all external power sources.
- Follow the Newport e360 service procedure for safe access to the control module and associated cable connections.
- Record the routing and connector orientation of the installed cable before removal.
- Disconnect the existing cable by handling the connectors rather than pulling on the cable conductors.
- Install the Newport Medical AG-AP1085 cable in the designated position, maintaining the specified routing and avoiding pinching, sharp bends, or contact with moving parts.
- Confirm that each connector is fully seated and that the cable is secured as required by the service documentation.
- Reassemble the ventilator and complete all prescribed operational, alarm, and safety checks before returning the device to patient use.