Inspire Innovations international limited.
Type the part number or keyword in the search box. If you do not know the catalog number, you can find the product by category or by manufacturer. To find a product by device model, first select the manufacturer.
Linet 78061, 8210-3406A Linet Eleganza 3XC linear motor with unblocking IPX6
Linet 78061, 8210-3406A Linear Motor with Unblocking IPX6 for Eleganza 3XC
Product Purpose and Features
The Linet 78061, 8210-3406A linear motor is a LINET-manufactured actuator designed for the Linet Eleganza 3XC medical bed. It provides controlled linear movement within the bed’s adjustment system and includes an unblocking function for mechanical release when required.
With an IPX6 enclosure protection rating, the motor is protected against powerful water jets. This rating does not indicate protection against immersion, and no dust-protection classification is specified. The actuator is intended for replacement or servicing of the corresponding Eleganza 3XC bed mechanism.
Technical Specifications
- Manufacturer: LINET
- Catalog number: 78061
- Manufacturer reference: 8210-3406A
- Product type: Linear motor / medical bed actuator
- Function: Controlled linear movement of a bed adjustment mechanism
- Release feature: Unblocking function
- Enclosure protection rating: IPX6
- Intended equipment: LINET Eleganza 3XC medical bed
Compatible Medical Devices
This linear motor is compatible with the LINET Eleganza 3XC medical bed when the installed actuator is identified by catalog number 78061 or reference 8210-3406A. Compatibility should be confirmed using the identification label on the existing component and the applicable LINET service documentation before installation.
Installation and Usage Instructions
- Disconnect the medical bed from its electrical supply and remove any load from the moving mechanism before servicing.
- Verify that the replacement actuator references 78061 and 8210-3406A match the component being replaced.
- Install the linear motor in the designated Eleganza 3XC mounting position using the original connection points and approved hardware.
- Connect the actuator only to the specified bed control system and route cables so they cannot be pinched, stretched, or damaged by moving parts.
- After installation, test the complete adjustment range and unblocking function without a patient on the bed.
- Return the bed to clinical use only after confirming secure mounting, correct movement, and proper operation of all relevant safety functions.
Installation, inspection, and functional testing should be performed by qualified medical-equipment service personnel in accordance with LINET maintenance procedures. Do not immerse the actuator or use it if the housing, cable, connectors, or mounting points are damaged.
Worldwide Supply from Partsformed
Partsformed offers worldwide shipping, competitive prices, and high-quality products for medical-equipment maintenance and repair. The Linet 78061, 8210-3406A Eleganza 3XC linear motor is a precise replacement choice for facilities and service organizations maintaining compatible LINET hospital beds.