Karl Storz 847000W Bipolar High Frequency Cord
Karl Storz 847000W Bipolar High Frequency Cord
The Karl Storz 847000W Bipolar High Frequency Cord is a 3 m electrosurgical cable designed to transmit bipolar high-frequency energy between a compatible electrosurgical generator and a bipolar surgical instrument. Manufactured by KARL STORZ, this dedicated medical cable supports reliable connection during bipolar coagulation and other procedures performed with compatible instrumentation.
Product Features
- Designed for bipolar high-frequency electrosurgical applications
- Connects a compatible bipolar instrument to an approved HF generator
- Three-metre cable provides practical reach within the operating room
- Compatible with multiple KARL STORZ, ERBE and Valleylab electrosurgical platforms
- Dedicated catalog reference simplifies identification and replacement
Technical Specifications
- Manufacturer: KARL STORZ
- Catalog number: 847000W
- Product type: Bipolar high-frequency cord
- Energy configuration: Bipolar HF
- Cable length: 300 cm
- Equivalent length: 3 m
- Application: Connection of compatible bipolar surgical instruments to an electrosurgical generator
Compatible Medical Devices and Models
The Karl Storz 847000W cord is specified for use with the following electrosurgical generator platforms:
- KARL STORZ AUTOCON II 400 SCB
- KARL STORZ AUTOCON II 200
- KARL STORZ AUTOCON II 80
- ERBE ICC 350
- ERBE VIO 300 D
- Compatible Valleylab electrosurgical units equipped with the corresponding bipolar connection
Compatibility must also be confirmed at the instrument end. Use the cable only with bipolar instruments and generator receptacles designated for this connection by the applicable equipment instructions.
Usage Instructions
- Before use, inspect the complete cord, insulation and both connectors. Do not use the cable if it is cracked, loose, deformed or otherwise damaged.
- Place the electrosurgical generator in standby or switch it off before making connections.
- Insert the generator-side connector into the designated bipolar output and connect the opposite end to the compatible bipolar instrument. Hold the connector body rather than pulling or twisting the cable.
- Confirm secure connections and select operating parameters in accordance with the generator and surgical instrument instructions for use.
- During the procedure, protect the cable from sharp edges, excessive tension, hot surfaces and liquids around electrical connections.
- Return the generator to standby before disconnecting the cord.
- After use, clean, disinfect, sterilize when required, and store the cable strictly according to the current KARL STORZ reprocessing instructions.
Ordering from Partsformed
Partsformed supplies the Karl Storz 847000W Bipolar High Frequency Cord with worldwide shipping, competitive prices and a focus on high-quality medical products. Verify the catalog number, generator platform and instrument connector before ordering to ensure the correct configuration for your electrosurgical system.