Inspire Innovations international limited.
Type the part number or keyword in the search box. If you do not know the catalog number, you can find the product by category or by manufacturer. To find a product by device model, first select the manufacturer.
Karl Storz 277Y Unipolar high frequency cord with 4 mm plug 300 cm
Karl Storz 277Y Unipolar High Frequency Cord with 4 mm Plug, 300 cm
Product Description
The Karl Storz 277Y unipolar high frequency cord is an electrosurgical connection accessory designed to transmit high-frequency energy between a compatible HF generator and a unipolar surgical instrument. Its 300 cm length provides flexibility when arranging equipment in the operating room, while the 4 mm plug supports connection to an approved unipolar generator output.
Manufactured by Karl Storz under catalog number 277Y, this HF cord is intended for professional medical use with equipment that specifically supports its connector type and configuration.
Key Features
- Designed for unipolar high-frequency electrosurgical applications
- 4 mm plug for connection to a matching approved HF generator socket
- 300 cm cable length for convenient equipment positioning
- Karl Storz catalog and model number 277Y
- Connects a compatible unipolar surgical instrument to an electrosurgical generator
Technical Specifications
- Manufacturer: Karl Storz
- Catalog number: 277Y
- Model: 277Y
- Product type: High-frequency electrosurgical cord
- Operating configuration: Unipolar
- Generator-side connector: 4 mm plug
- Cord length: 300 cm
- Cord length in meters: 3 m
Compatible Medical Devices and Instruments
The Karl Storz 277Y HF cord is compatible with Karl Storz unipolar instruments specifically designated for use with cord model 277Y. It may be connected only to an electrosurgical generator that has a matching 4 mm unipolar output and whose operating instructions approve this cord and instrument configuration.
- Karl Storz unipolar surgical instruments specified for use with catalog number 277Y
- Compatible HF electrosurgical generators equipped with an approved 4 mm unipolar connection
- Medical device configurations in which the generator, cord and applied instrument are explicitly approved for operation together
Connector dimensions alone do not confirm compatibility. Verify the applicable Karl Storz instrument instructions and the HF generator manual before use. The 277Y is a unipolar cord and must not be connected to a bipolar output.
Usage Instructions
- Confirm that the electrosurgical generator and surgical instrument are approved for use with the Karl Storz 277Y cord.
- Switch the generator off or place it in the required standby condition before making connections.
- Inspect the entire cord, connector and insulation before each procedure. Do not use the cord if it is damaged, deformed or shows exposed conductors.
- Insert the 4 mm plug fully into the designated unipolar HF generator output.
- Connect the opposite end to the compatible unipolar instrument as directed by the instrument instructions.
- Route the cord without sharp bends, crushing, excessive tension or contact with hazardous surfaces.
- Select generator settings according to the generator manual, instrument instructions and clinical procedure.
- After use, deactivate the generator before disconnecting the cord. Handle and reprocess the product strictly according to the current Karl Storz instructions for use.
Ordering from Partsformed
Partsformed supplies high-quality medical equipment components at competitive prices and offers worldwide shipping. Order the Karl Storz 277Y unipolar high frequency cord with 4 mm plug, 300 cm by confirming catalog number 277Y and the compatibility requirements of your electrosurgical system.