Inspire Innovations international limited.
Type the part number or keyword in the search box. If you do not know the catalog number, you can find the product by category or by manufacturer. To find a product by device model, first select the manufacturer.
Karl Storz 277 Monopolar High-Frequency Cord
Karl Storz 277 Monopolar High-Frequency Cord
The Karl Storz 277 Monopolar High-Frequency Cord is an electrosurgical connection cable manufactured by Karl Storz. Catalog number 277 is designed to connect a compatible monopolar surgical instrument to a high-frequency electrosurgical generator, enabling transmission of HF energy during procedures that require monopolar cutting or coagulation.
Purpose and Features
- Provides an electrical connection between compatible monopolar instruments and HF electrosurgical equipment.
- Intended for monopolar high-frequency electrosurgery.
- Original Karl Storz product identified by catalog number 277.
- Suitable for professional use in operating rooms and other appropriately equipped clinical environments.
- Supports organized replacement and maintenance of compatible Karl Storz electrosurgical systems.
Technical Specifications
- Manufacturer: Karl Storz
- Product name: Monopolar High-Frequency Cord
- Catalog number: 277
- Model: 277
- Product type: Electrosurgical connecting cord
- Electrosurgical configuration: Monopolar
- Signal type: High-frequency electrosurgical energy
- Application: Connection of a compatible monopolar instrument to an HF generator
Compatible Medical Devices
The Karl Storz 277 HF cord is intended for use with Karl Storz monopolar surgical instruments and high-frequency electrosurgical generators whose equipment documentation explicitly specifies compatibility with cable model 277. Connector design and generator requirements can vary between systems, so the catalog number, instrument interface, generator connection, and current instructions for use must be checked before installation. The cord should not be treated as a universal electrosurgical cable or connected through unapproved adapters.
Usage Instructions
- Confirm that the monopolar instrument and electrosurgical generator specify compatibility with the Karl Storz 277 cord.
- Before each procedure, inspect the cable, insulation, plugs, and strain-relief areas for cuts, cracks, deformation, exposed conductors, or other damage.
- Ensure that the HF generator is switched off or placed in its safe connection state before attaching the cable.
- Connect the appropriate end to the compatible monopolar instrument and the other end to the designated generator output, following the instructions supplied with both devices.
- Verify secure seating of both connections and route the cable to prevent tension, sharp bends, crushing, or contact with hot surfaces.
- Select generator mode and power settings according to the generator instructions, the connected instrument, and the clinical procedure.
- After use, deactivate the generator and disconnect the cord by holding the plug rather than pulling on the cable.
- Handle, clean, disinfect, reprocess, inspect, and store the product strictly according to the current Karl Storz instructions applicable to catalog number 277 and the healthcare facility’s validated procedures.
Safety Information
Use this monopolar electrosurgical cord only by trained medical personnel. Do not use a cable with damaged insulation, loose connectors, burn marks, excessive bending, or uncertain compatibility. Follow all generator, instrument, patient-return-electrode, and electrosurgical safety requirements before activating HF energy.
Order Karl Storz 277 from Partsformed
Partsformed supplies the Karl Storz 277 Monopolar High-Frequency Cord for medical equipment maintenance and clinical procurement. Customers benefit from worldwide shipping, competitive prices, and high-quality products. Verify the manufacturer, catalog number 277, and compatibility with your electrosurgical system before ordering.
