Inspire Innovations international limited.
Type the part number or keyword in the search box. If you do not know the catalog number, you can find the product by category or by manufacturer. To find a product by device model, first select the manufacturer.
Karl Storz 26176LW Bipolar High Frequency Cord, 300 cm
Karl Storz 26176LW Bipolar High Frequency Cord, 300 cm
The Karl Storz 26176LW Bipolar High Frequency Cord is a medical-grade connection cable designed to transmit bipolar electrosurgical energy between a compatible high-frequency generator and a KARL STORZ bipolar instrument. Its 300 cm length provides flexible equipment positioning in the operating room while maintaining a reliable connection during electrosurgical procedures.
Manufactured by Karl Storz, this bipolar HF cord features a generator-side connection for compatible Richard Wolf electrosurgical equipment. The cable does not generate high-frequency energy independently and must be used only with devices that explicitly specify the 26176LW cord or the corresponding Wolf bipolar interface.
Product Features
- Designed for transmission of bipolar high-frequency electrosurgical energy
- Connects a compatible KARL STORZ bipolar instrument to an appropriate HF generator
- 300 cm cable length supports convenient generator placement
- Wolf-type generator connection
- Dedicated bipolar configuration for compatible electrosurgical applications
- Original product manufactured by Karl Storz
Technical Specifications
- Manufacturer: Karl Storz
- Catalog number: 26176LW
- Product type: Bipolar high-frequency cord
- Cable length: 300 cm
- Length in metres: 3 m
- Electrosurgical mode: Bipolar
- Generator-side interface: Wolf-type bipolar connection
- Function: Connection between a compatible bipolar surgical instrument and HF electrosurgical generator
Compatible Medical Devices
The Karl Storz 26176LW cable is intended for use with the following device categories:
- KARL STORZ bipolar instruments whose instructions or accessory list specify cord model 26176LW
- Richard Wolf high-frequency surgical generators equipped with the matching bipolar socket
- Electrosurgical systems expressly approved by their manufacturer for a Wolf-type bipolar cable connection
Compatibility must be confirmed using the instrument and generator instructions before use. Connector appearance alone is not sufficient to establish compatibility, and the cord must not be connected to monopolar outputs.
Usage Instructions
- Place the compatible HF generator in the off or standby state before connecting the cable.
- Inspect the complete cord, insulation and both connectors. Do not use the product if it is damaged, cracked, loose or visibly worn.
- Connect the instrument-side plug to the compatible KARL STORZ bipolar instrument.
- Insert the generator-side plug into the matching Wolf bipolar output specified by the generator manufacturer.
- Ensure that both connectors are fully seated without forcing or modifying them.
- Select bipolar mode and configure the generator according to the instructions for the generator, instrument and planned procedure.
- Perform the prescribed system and functional checks before clinical use.
- During operation, protect the cable from excessive tension, sharp bends, crushing and contact with hot instruments.
- After the procedure, return the generator to standby or switch it off. Disconnect the cord by holding the connector bodies rather than pulling on the cable.
- Clean, disinfect, sterilize and store the cord only in accordance with the current Karl Storz instructions for use and the healthcare facility’s validated procedures.
This electrosurgical accessory is intended for use by trained medical personnel. Generator settings, preparation and clinical application must follow the instructions supplied with every connected device.
Order Karl Storz 26176LW from Partsformed
Partsformed supplies high-quality products for medical equipment, including the Karl Storz 26176LW Bipolar High Frequency Cord, 300 cm. Customers benefit from competitive prices and worldwide shipping. Verify the catalog number, generator interface and instrument compatibility before ordering.