Inspire Innovations international limited.
Type the part number or keyword in the search box. If you do not know the catalog number, you can find the product by category or by manufacturer. To find a product by device model, first select the manufacturer.
Karl Storz 26176LV Bipolar High Frequency Cord
Karl Storz 26176LV Bipolar High Frequency Cord
The Karl Storz 26176LV Bipolar High Frequency Cord is a reusable electrosurgical connection cable designed to link compatible KARL STORZ bipolar coagulation instruments with suitable Valleylab electrosurgical coagulators. Its 300 cm length provides practical reach between the sterile operating field and the electrosurgical unit while transmitting bipolar high-frequency energy to the connected instrument.
Product Purpose and Features
- Designed for bipolar high-frequency electrosurgical applications.
- Connects compatible KARL STORZ bipolar coagulation instruments to supported Valleylab coagulators.
- Provides a 300 cm working length for convenient equipment positioning.
- Reusable design intended for professional clinical environments.
- Manufacturer-specific configuration helps ensure a secure connection when used with equipment that specifies catalog number 26176LV.
Technical Specifications
- Manufacturer: KARL STORZ
- Catalog number: 26176LV
- Product type: Bipolar high-frequency cord
- Electrosurgical mode: Bipolar
- Cord length: 300 cm
- Instrument compatibility: Compatible KARL STORZ bipolar coagulation instruments
- Generator compatibility: Compatible Valleylab coagulators
- Use category: Reusable electrosurgical accessory
Compatible Medical Equipment
The Karl Storz 26176LV cable is intended for KARL STORZ bipolar coagulation instruments whose instructions specify the 26176LV cord. The generator-side connector is configured for compatible Valleylab coagulators. Before use, confirm the catalog number, connector type, and compatibility requirements in the instructions supplied with both the surgical instrument and electrosurgical unit. Compatibility should not be assumed solely from brand name or visual connector similarity.
Usage Instructions
- Confirm that the bipolar instrument and Valleylab coagulator both specify compatibility with the 26176LV cord or its connector configuration.
- Before each procedure, inspect the cable, insulation, plugs, and strain-relief areas. Do not use the cord if damage, cracking, exposed conductors, deformation, or loose connections are present.
- Place the electrosurgical unit in standby or switch it off before making connections.
- Insert the instrument-side and generator-side plugs fully into their designated bipolar connections.
- Select and operate the bipolar function only in accordance with the instructions for the electrosurgical generator and connected instrument.
- After use, disconnect the cord by handling the plugs rather than pulling on the cable.
- Clean, disinfect, sterilize, inspect, and store the cord strictly according to the current KARL STORZ reprocessing instructions.
Ordering from Partsformed
Partsformed supplies the Karl Storz 26176LV Bipolar High Frequency Cord and other high-quality medical equipment accessories at competitive prices. Worldwide shipping is available to support hospitals, surgical centers, clinics, and medical equipment service organizations in multiple regions.
