Inspire Innovations international limited.
Type the part number or keyword in the search box. If you do not know the catalog number, you can find the product by category or by manufacturer. To find a product by device model, first select the manufacturer.
DRAEGER SAFETY R54450 Panorama Nova Standard P Full Face Mask
DRAEGER SAFETY R54450 Panorama Nova Standard P Full Face Mask
The DRAEGER SAFETY R54450 Panorama Nova Standard P Full Face Mask is a reusable respiratory facepiece designed for professional use with compatible positive-pressure breathing apparatus. Manufactured by DRAEGER SAFETY (Drager Safety), it combines a durable EPDM mask body, a wide-view polycarbonate visor and a secure five-point head harness. The Panorama Nova design protects the eyes, face and respiratory tract while supporting clear visibility and voice communication in hazardous environments.
Purpose and Key Features
- Full-face respiratory protection for use with compatible supplied-air and self-contained breathing apparatus.
- Drager P plug-in connection for a matching positive-pressure lung demand valve.
- EPDM facepiece offering durability and resistance to demanding working conditions.
- Polycarbonate visor providing a broad field of vision and impact resistance.
- Integrated inner mask helps direct airflow and reduce visor fogging.
- Five-point head harness supports stable positioning and even pressure distribution.
- Built-in speech diaphragm assists verbal communication while the mask is worn.
- Reusable construction allows cleaning, disinfection, inspection and servicing according to Drager instructions.
Technical Specifications
- Manufacturer: DRAEGER SAFETY / Drager Safety
- Product name: Panorama Nova Standard P
- Catalog number: R54450
- Product type: Reusable full face mask for respiratory protective equipment
- Mask body material: EPDM
- Visor material: Polycarbonate
- Connector: Drager P plug-in connector
- Operating principle: Positive-pressure operation with a compatible lung demand valve
- Head harness: Five-point adjustable harness
- Communication component: Integrated speech diaphragm
- Protection class: EN 136 Class 3
- Fit designation: Standard
Compatible Breathing Apparatus and Models
The R54450 face mask connects to a Drager positive-pressure lung demand valve with the P plug-in interface. It can be used with compatible configurations of the following Drager self-contained breathing apparatus:
- Drager PSS 3000
- Drager PSS 4000
- Drager PSS 5000
- Drager PSS 7000
Compatibility depends on the lung demand valve and connector installed on the breathing apparatus. The valve must use the matching Drager P connection. This industrial respiratory facepiece is not a medical oxygen mask and should not be connected directly to medical gas equipment.
Usage Instructions
- Confirm that the face mask, breathing apparatus and lung demand valve are approved for use together and have been inspected by trained personnel.
- Examine the visor, sealing edge, harness, connector, valves and speech diaphragm. Do not use the mask if any component is damaged, contaminated or incomplete.
- Fully loosen the harness straps, place the chin into the chin cup and draw the harness over the head.
- Tighten the lower, side and upper straps evenly without overtightening or distorting the face seal.
- Perform the prescribed leak and seal checks. Facial hair, eyewear temples or other objects crossing the sealing surface can prevent an airtight fit.
- Attach the compatible P-type positive-pressure lung demand valve and verify correct engagement before entering the hazardous area.
- During operation, leave the area immediately if breathing resistance increases, the seal fails, visibility becomes unsafe or the air supply warning activates.
- After use, disconnect the lung demand valve in a safe atmosphere. Clean and disinfect the mask using products and procedures approved by Drager.
- Rinse as required, allow the mask to dry away from direct heat and sunlight, and inspect it before storage. Maintenance and component replacement must follow the official Drager service schedule.
Ordering from Partsformed
Partsformed supplies the genuine DRAEGER SAFETY R54450 Panorama Nova Standard P Full Face Mask with worldwide shipping, competitive prices and a commitment to high-quality products. Always verify the P connector and breathing-apparatus configuration before ordering to ensure a safe and correct match.