Inspire Innovations international limited.
Type the part number or keyword in the search box. If you do not know the catalog number, you can find the product by category or by manufacturer. To find a product by device model, first select the manufacturer.
Covidien E7507 ADULT REM POLYHESIVE II PATIENT RETURN ELECTRODE (package of 50)
Covidien E7507 Adult REM PolyHesive II Patient Return Electrode, Package of 50
The Covidien E7507 Adult REM PolyHesive II Patient Return Electrode is a disposable electrosurgical grounding pad designed to provide a controlled return path for radiofrequency current during monopolar electrosurgery. Its split-electrode configuration supports REM return electrode monitoring, allowing a compatible Valleylab electrosurgical generator to monitor pad-to-patient contact and respond when contact quality falls outside acceptable limits.
Purpose and Product Features
- Designed for adult patients undergoing monopolar electrosurgical procedures.
- Split return-electrode design supports REM contact-quality monitoring.
- PolyHesive II conductive adhesive promotes consistent contact with the patient’s skin.
- Flexible construction conforms to an appropriately selected application area.
- Non-corded configuration connects through a compatible reusable patient return electrode cable.
- Single-use design helps support infection-control and operating-room workflow requirements.
- Supplied in a package of 50 electrodes for hospitals, surgical centers and other clinical facilities.
Technical Specifications
- Manufacturer: Covidien
- Catalog number: E7507
- Product family: REM PolyHesive II
- Product type: Patient return electrode for monopolar electrosurgery
- Patient category: Adult
- Electrode configuration: Split REM electrode
- Connection type: Non-corded electrode for use with a compatible reusable return-electrode cable
- Conductive surface area: 15 square inches, approximately 97 square centimeters
- Use classification: Disposable, single use
- Package quantity: 50 electrodes
Compatible Electrosurgical Equipment
Covidien E7507 electrodes are intended for use with Valleylab electrosurgical generators and energy platforms equipped with the REM Return Electrode Monitoring system. Compatible equipment includes the following product families when connected with the correct manufacturer-approved return-electrode cable:
- Valleylab Force FX electrosurgical generators
- Valleylab Force EZ electrosurgical generators
- Valleylab Force 2 generators equipped for REM monitoring
- Valleylab ForceTriad energy platforms
- Other Covidien or Valleylab electrosurgical units that specify compatibility with REM PolyHesive patient return electrodes
The E7507 non-corded pad can be used with the compatible Valleylab E0560 reusable REM patient return electrode cord. Generator, cable and electrode compatibility should always be confirmed in the applicable equipment instructions before a procedure.
Application and Usage Instructions
- Inspect the electrode package and do not use the pad if the packaging or electrode is damaged.
- Select a well-vascularized, muscular and convex area near the operative site. Avoid bony prominences, scar tissue, excessive adipose tissue, metal implants and areas where fluid may collect.
- Remove excess hair if necessary, then clean and thoroughly dry the selected skin area. Do not apply the electrode over wet skin or lotions.
- Remove the protective liner without touching or contaminating the conductive adhesive surface.
- Apply the entire electrode smoothly to the skin, ensuring full contact across both sections. Do not fold, cut or overlap the pad.
- Connect the electrode tab to the compatible reusable REM cable, then connect the cable to the electrosurgical generator.
- Confirm that the generator recognizes acceptable return-electrode contact before activating monopolar electrosurgery.
- If a REM alarm occurs, stop activation and inspect the electrode, cable and patient contact according to the generator instructions. Do not disable or bypass the monitoring system.
- After the procedure, peel the electrode away gently while supporting the skin. Inspect the application site and discard the electrode after one use.
Application and operation must be performed by trained medical personnel in accordance with the electrode, cable and electrosurgical generator instructions for use.
Order Covidien E7507 Electrodes from Partsformed
Partsformed supplies the Covidien E7507 Adult REM PolyHesive II Patient Return Electrode, package of 50, for professional electrosurgical applications. Partsformed offers worldwide shipping, competitive prices and high-quality products for hospitals, clinics, surgical centers and medical-equipment service organizations.
