Inspire Innovations international limited.
Type the part number or keyword in the search box. If you do not know the catalog number, you can find the product by category or by manufacturer. To find a product by device model, first select the manufacturer.
Covidien E0021S REUSABLE BIPOLAR FORCEPS CORD
Covidien E0021S Reusable Bipolar Forceps Cord
The Covidien E0021S reusable bipolar forceps cord is an electrosurgical accessory designed to connect compatible standard bipolar forceps to a Covidien/Valleylab electrosurgical generator. It carries bipolar radiofrequency energy from the generator to the connected instrument for controlled coagulation during procedures performed by trained medical professionals. Its reusable construction and 12 ft cable length support convenient equipment positioning in the operating room.
Product Features
- Original Covidien electrosurgical accessory
- Designed for compatible standard bipolar forceps
- Reusable cord for repeated clinical use after approved reprocessing
- 12 ft length provides flexibility between the sterile field and electrosurgical generator
- Insulated cable construction for bipolar electrosurgical applications
- Suitable for use with compatible Covidien/Valleylab bipolar generator receptacles
Technical Specifications
- Manufacturer: Covidien
- Catalog number: E0021S
- Product type: Reusable bipolar forceps cord
- Cable length: 12 ft (approximately 3.7 m)
- Application: Connection of compatible bipolar forceps to an electrosurgical generator
- Instrument compatibility: Standard bipolar forceps designed for the E0021S connection
- Reuse classification: Reusable
- Energy mode: Bipolar electrosurgery
Compatible Medical Devices
The Covidien E0021S cord is intended for compatible Covidien/Valleylab electrosurgical systems equipped with the appropriate bipolar receptacle, including the Valleylab ForceTriad energy platform and Valleylab FT10 energy platform when their instructions specify support for this reusable bipolar cord and the connected standard bipolar forceps. Compatibility depends on both the generator-side receptacle and the forceps connector. Confirm catalog number E0021S in the equipment and instrument instructions before use; this cord is not a substitute for a monopolar cable or a dedicated vessel-sealing handpiece cable.
Usage Instructions
- Inspect the complete cord, insulation, strain reliefs, and connectors before every procedure. Do not use the cord if it is cut, cracked, loose, deformed, or otherwise damaged.
- Keep the electrosurgical generator switched off or in standby while making connections.
- Attach the cord securely to compatible standard bipolar forceps without forcing or modifying the connector.
- Insert the generator-side connector fully into the designated bipolar receptacle of the compatible electrosurgical unit.
- Route the cable to prevent sharp bends, tension, contact with hot surfaces, or entanglement with other equipment.
- Select and activate bipolar output only in accordance with the generator, forceps, and procedure instructions.
- After use, place the generator in standby or switch it off, then disconnect the cord by holding the connector rather than pulling the cable.
- Clean, inspect, package, and sterilize the reusable cord according to the current Covidien reprocessing instructions and the healthcare facility’s validated protocol.
Order Covidien E0021S from Partsformed
Partsformed supplies the Covidien E0021S reusable bipolar forceps cord for hospitals, surgical centers, and medical equipment providers. Customers benefit from competitive prices, high-quality products, and worldwide shipping. Always match the manufacturer, catalog number, generator receptacle, and bipolar forceps connection before ordering.