Inspire Innovations international limited.
Type the part number or keyword in the search box. If you do not know the catalog number, you can find the product by category or by manufacturer. To find a product by device model, first select the manufacturer.
BioSan BS-010213-S07
BioSan BS-010213-S07 BN-16/100 Centrifuge Tube Adapter
BioSan BS-010213-S07 is a BN-16/100 tube adapter designed for the BR-4 swing-out rotor used with the BioSan LMC-56 laboratory centrifuge. This original BioSan centrifuge accessory supports properly sized tubes inside the rotor bucket, helping operators arrange samples securely and maintain a balanced loading pattern during centrifugation.
Purpose and Features
- Designed to accommodate laboratory tubes measuring up to 16 mm in diameter and 100 mm in length.
- Fits the BR-4 swing-out rotor configuration of the BioSan LMC-56 centrifuge.
- Supports stable tube positioning within the rotor bucket.
- Suitable for routine sample preparation and separation workflows performed with compatible laboratory tubes.
- Manufacturer-specific design provides dependable compatibility with the designated BioSan rotor and centrifuge.
Technical Specifications
- Manufacturer: BioSan
- Catalog number: BS-010213-S07
- Model: BN-16/100
- Product type: Centrifuge tube adapter
- Maximum tube diameter: 16 mm
- Maximum tube length: 100 mm
- Compatible rotor: BioSan BR-4 swing-out rotor
- Compatible centrifuge: BioSan LMC-56 laboratory centrifuge
Compatible Medical and Laboratory Equipment
The BioSan BS-010213-S07 BN-16/100 adapter is intended for the BioSan LMC-56 laboratory centrifuge when equipped with the BR-4 swing-out rotor. Use it only with the specified rotor arrangement and tubes that do not exceed the stated dimensional limits. Centrifugation speed, load, and relative centrifugal force must remain within the limits defined for the centrifuge, rotor, buckets, tubes, and processed samples.
Usage Instructions
- Switch off the LMC-56 centrifuge and wait until the BR-4 rotor has stopped completely.
- Inspect the BN-16/100 adapter, rotor, and bucket for contamination, deformation, cracks, or other visible damage.
- Place the adapter correctly into the appropriate BR-4 rotor bucket.
- Insert a compatible tube with a diameter of no more than 16 mm and a length of no more than 100 mm.
- Distribute tubes symmetrically and balance opposing loads according to the LMC-56 and BR-4 operating instructions.
- Confirm that tubes are seated securely before closing the centrifuge lid and starting the selected program.
- After use, remove samples carefully and clean the adapter using procedures and agents approved for the accessory and processed material.
Ordering from Partsformed
Partsformed supplies the BioSan BS-010213-S07 BN-16/100 centrifuge adapter with worldwide shipping, competitive prices, and high-quality products. The catalog number enables precise identification when ordering a replacement or additional adapter for a compatible BioSan LMC-56 centrifuge and BR-4 rotor.