Inspire Innovations international limited.
Type the part number or keyword in the search box. If you do not know the catalog number, you can find the product by category or by manufacturer. To find a product by device model, first select the manufacturer.
OPT316 CANNULA NASAL OPTIFLOW NEONATAL JUNIOR
OPT316 CANNULA NASAL OPTIFLOW NEONATAL JUNIOR
The OPT316 Cannula Nasal Optiflow Neonatal Junior, produced by Fisher & Paykel Healthcare, represents a significant advancement in neonatal respiratory care. This specialized medical device is meticulously designed to deliver optimal respiratory support to neonatal and pediatric patients through High Flow Nasal Cannula (HFNC) therapy. Here, we delve into the technical aspects that make this product a critical component in neonatal respiratory support.
Material and Composition
The OPT316 Cannula is fabricated from biocompatible, medical-grade silicone and thermoplastic elastomers, ensuring both durability and patient comfort. The materials used are hypoallergenic, minimizing the risk of adverse reactions in sensitive neonatal skin.
Size and Fit
This particular model is engineered for neonatal and junior patients, catering to varying sizes of nares to ensure a secure and comfortable fit. The cannula prongs are designed to have an anatomical fit, reducing pressure on the sensitive nasal tissues and preventing nasal trauma. The system includes three distinct sizes to accommodate a range of patients typically weighing up to 8 kilograms.
High Flow Therapy
The OPT316 Cannula is integral to the Optiflow Junior system, designed for the administration of HFNC therapy. This therapy delivers humidified and warmed oxygen or air at high flow rates, which assists in improving oxygenation, reducing work of breathing, and aiding in the clearance of CO?. The flow rates for neonatal purposes vary, adjustable based on the patient's needs, usually between 2 to 8 liters per minute.
Humidification
Effective humidification is critical for preventing airway drying and maintaining mucociliary function. The OPT316 leverages Fisher & Paykel’s proprietary MR850 or MR730 humidifiers, ensuring that the gas mixture is optimally humidified and warmed to mimic physiological conditions, which helps in maintaining mucosal integrity and reducing the risk of bronchoconstriction or other complications.
Soft Prongs and Secure Fitment
The soft, flexible prongs ensure minimal discomfort during prolonged use, allowing the cannula to be worn comfortably for extended periods. The prong design also minimizes the risk of nasal pressure sores. Adjustable headgear ensures the cannula remains securely positioned, even with active neonates.
Acoustic Considerations
Special attention has been given to minimizing the noise produced by the device, which is particularly critical in neonatal intensive care settings. Reduced operational noise helps create a quieter and less stressful environment for the patient, promoting better overall outcomes.
Anti-asphyxiation Design
The cannula includes an anti-asphyxiation valve to ensure patient safety. This safety feature guarantees that if the flow generator fails or is disconnected, room air can still be breathed adequately, providing an essential fail-safe for patient safety.
Securing Mechanism
The headgear includes a non-slip, sensitive material and a Velcro securing mechanism, allowing for easy and secure attachment that avoids excessive tightness and pressure points on the infant’s delicate skin.
System Integration
The OPT316 Cannula is designed to seamlessly integrate with the full Optiflow Junior system, including humidifiers and flow generators produced by Fisher & Paykel. This integration ensures compatibility and ease of assembly, reducing the risk of mismatches or installation errors.
Versatility
The OPT316 is versatile, suitable for use in various clinical settings, including ICU, NICU, and home care under medical supervision, providing consistency in treatment regardless of the care environment.
